LA-126 MULTICHANNEL MONITOR CONTROLLER

LA–126 MULTICHANNEL MONITOR CONTROLLER

The LA 126 is especially designed as a multichannel level controller.
LA-126 can control up to 16 channels

3 FUNCTIONS:


  • STEREO 1. 2 channels control ( left/right. input/output 13/14 )
  • 7.1.4 12 channels control ( Dolby Atmos. input/output 1/12 )
  • STEREO 2. 2 channels control ( left/right. input/output 15/16 )

Illuminated 3 position rotative switch
Level control by VCA. One knob only controls all the 16 outputs.

LA-126 can be used as a remote control if it is placed outside of the desk. DB-25 pole connectors on back panel

LEVEL CONTROL

  • The correct use of the la-126 unit requires a proper level regulation procedure
  • Send to the la-126 unit the signal with the right work level
  • Set the level control of the la-126 unit in position “two o’clock”
  • Increase the external amplifier level control in order to have the correct listening level
  • In some cases it is necessary to insert an external attenuator at the amplifiers’s input
  • LA-126 REMOTE


    Insert the jack only when the unit is turned off

    The insertion of the rear jack deactivates the control on the front panel

    The insertion of the front jack deactivates both the control on the front panel and the remote insert on the rear jack

    Technical specifications

    Channels total 16
    1-12 reserved for Dolby Atmos; 13-14 Stereo1; 15-16 Stereo2
    Input
    Input level
    Input impedance
    Electronically balanced
    +4dBu, Max +28dBu
    > 10 kΩ
    Output
    Output Level
    Output impedance
    Electronically Balanced
    -25dBu > Max 0dBu
    100Ω ( minimum external load 600Ω )
    Bandwidth 10 - 100.000 Hz @ -1dB perfect square wave up to 20kHz
    Distortion + Noise <0.005% ( typical 0.001 %)
    Connectors
    Input-Output
    Remote Control

    DB 25 on Rear Panel
    Jack TRS on Front and Rear Panels
    Functions
    Design
    Three In/Out Selection
    Switching system

    100% high-end analog design
    Stereo1; Dolby Atmos; Stereo2
    Sealed Relays. Not used outputs are grounded to avoid noise and cross-talking
    Power Supply
    Operating Voltage
    Power Consumption
    Rear Panel AC mains
    Switching Double filtered + Linear Regulators
    110 - 230V 50-60 Hz
    20 W
    IEC C13 16 A connector, AC mains cord with IEC Schuko
    Construction
    Dimensions
    Weight
    1Unit, 19" rack mount stainless steel
    W 483mm 19"/ H 44 mm /1.75 " D 250 mm /9.8"
    4 kg